二维搜索
Sketch the part you are looking for or have a photo described in text form
Create image description with AI
Create image description with AI
Drop file here
支持的文件格式: .PNG, .JPG, .JPEG, .WEBP
1/5
1
1
2|0
3
4
4
0
0
0
0
0
0
0
0
0
0

Doepke DFS2 025-2/0,03-F Hz60 09124028

Expand Table
1/5
Product preview
PREVIEW
Product number of the Manufacturer
MANUID
Manufacturer Type Description
MANUTYPEDESC
Level of Geometry
LOG
Short Description
DESCSHORT
Long Description
DESCLONG
International product number
INTNO
Manufacturer Name
MANUNAME
Delivery Time
DELTIME
Customs tariff number
CTN
Country of origin
COO
1
2
3
4
5
6
09114030
DFS2 016-2/0,03-F Hz60 V290
300
Doepke Residual current circuit-breakers 2-pole, 16 A, 0.03 A, Type F, 60 Hz/290 V, N left or right
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 2 are two-terminal residual current circuit-breakers for single-phase networks. In the standard design, the compact devices are just two module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. Devices in design V are made for special voltages. Properties: sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz; high immunity against surge currents and mains-voltage-operated secondary current impulses; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on". "off" and "tripped"; Connector C1 Neutral conductor position left or right; Mounting: quick fastening to mounting rail; any installation position; supply from any direction.
4014712273498
Doepke Schaltgeräte GmbH
0
85363010
DE
09124028HD
DFS2 025-2/0,03-F Hz60 HD
300
Doepke Residual current circuit-breakers 2-pole, 25 A, 0.03 A, Type F, 60 Hz/230 V, N left or right, HD
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 2 are two-terminal residual current circuit-breakers for single-phase networks. In the standard design, the compact devices are just two module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. With an airtight, encapsulated tripping mechanism from a special alloy and the stainless steel latch, residual current circuit-breakers in HD design are protected, in particular from corrosion, corrosive gases, moisture and extreme temperature fluctuations. Properties: sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz; high immunity against surge currents and mains-voltage-operated secondary current impulses; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on". "off" and "tripped"; Connector C1 Neutral conductor position left or right; Mounting: quick fastening to mounting rail; any installation position; supply from any direction.
4014712237001
Doepke Schaltgeräte GmbH
10
85363030
DE
09124028
DFS2 025-2/0,03-F Hz60
300
Doepke Residual current circuit-breakers 2-pole, 25 A, 0.03 A, Type F, 60 Hz/230 V, N left or right
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 2 are two-terminal residual current circuit-breakers for single-phase networks. In the standard design, the compact devices are just two module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. Properties: sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz; high immunity against surge currents and mains-voltage-operated secondary current impulses; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on". "off" and "tripped"; Connector C1 Neutral conductor position left or right; Mounting: quick fastening to mounting rail; any installation position; supply from any direction.
4014712236981
Doepke Schaltgeräte GmbH
10
85363030
DE
09134030
DFS2 040-2/0,03-F Hz60 V290
300
Doepke Residual current circuit-breakers 2-pole, 40 A, 0.03 A, Type F, 60 Hz/290 V, N left or right
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 2 are two-terminal residual current circuit-breakers for single-phase networks. In the standard design, the compact devices are just two module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. Devices in design V are made for special voltages. Properties: sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz; high immunity against surge currents and mains-voltage-operated secondary current impulses; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on". "off" and "tripped"; Connector C1 Neutral conductor position left or right; Mounting: quick fastening to mounting rail; any installation position; supply from any direction.
4014712273511
Doepke Schaltgeräte GmbH
0
85363030
DE
09134828HD
DFS4 040-4/0,03-F Hz60 HD
300
Doepke Residual current circuit-breakers 4-pole, 40 A, 0.03 A, Type F, 60 Hz/230 V, 400 V, N left, HD
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 4 are two-terminal or two-terminal pair residual current circuit-breakers for single- or three-phase networks. In the standard design, the compact devices are just four module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. With an airtight, encapsulated tripping mechanism from a special alloy and the stainless steel latch, residual current circuit-breakers in HD design are protected, in particular from corrosion, corrosive gases, moisture and extreme temperature fluctuations. Properties: sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz; high immunity against surge currents and mains-voltage-operated secondary current impulses; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on". "off" and "tripped"; Connector C1 Neutral conductor position left; Mounting: quick fastening to mounting rail; any installation position; supply from any direction.
4014712236967
Doepke Schaltgeräte GmbH
15
85363030
DE
09134828
DFS4 040-4/0,03-F Hz60
300
Doepke Residual current circuit-breakers 4-pole, 40 A, 0.03 A, Type F, 60 Hz/230 V, 400 V, N left
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 4 are two-terminal or two-terminal pair residual current circuit-breakers for single- or three-phase networks. In the standard design, the compact devices are just four module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. Properties: sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz; high immunity against surge currents and mains-voltage-operated secondary current impulses; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on". "off" and "tripped"; Connector C1 Neutral conductor position left; Mounting: quick fastening to mounting rail; any installation position; supply from any direction.
4014712239210
Doepke Schaltgeräte GmbH
15
85363030
DE
显示压缩表示(6 konfigurierbares Produkt)
订购编码09124028
上次修改15.12.2025 11:38:52
单位

分类

CNS

CNSERPBASE Object Properties
CNSPHYPROP Physical Properties
CNSPHYPROP Physical Properties

ECLASS 14.0

27-14-22-01 残余电流断路器
电压类型AC
保护方式IPIP20
27-14-22-01 残余电流断路器

ECLASS 13.0

27-14-22-01 残余电流断路器

ECLASS 12.0

27-14-22-01 残余电流断路器

ETIM 10.0

EC000003 Residual current circuit breaker (RCCB)

ETIM 9.0

EC000003 Residual current circuit breaker (RCCB)

ETIM 8.0

EC000003 Residual current circuit breaker (RCCB)
DIN railDIN-Schiene
ACAC
FF
60 Hz60 Hz
IP20IP20

Revit

RVT_METRICGENERICMODEL (Metric) Generic Model
Family categoryOST_ElectricalEquipment